V2000-c Rfid Access Control User Manual Fix
Standard 125 kHz (EM or compatible ID cards/fobs). Reading Distance: 3 to 6 cm. Operating Voltage: 12V DC ± 10%. Current Draw: < 60mA. Lock Output Load: Max 3A. Bell Output Load: Max 50mA.
The 3 key is used to delete individual users. V2000-c Rfid Access Control User Manual
The V2000-C system is designed to be reliable and durable, but like any system, it may require occasional troubleshooting and maintenance. The user manual provides a comprehensive guide on how to troubleshoot common issues and perform routine maintenance tasks. Standard 125 kHz (EM or compatible ID cards/fobs)
The represents a benchmark in standalone security solutions. Whether you are securing a single-door office, a co-working space, a storage unit facility, or a high-traffic commercial entrance, the V2000-c offers a robust blend of durability, cryptographic security, and user-friendly management. Current Draw: The 3 key is used to
| J1 Jumper Position | COM (J3) Connection | PUSH1 & COM State | Use Case | | :--- | :--- | :--- | :--- | | | GND | Normally Open | Fail-secure electric strike | | NC | GND | Normally Closed | Fail-safe magnetic lock | | NO | 12V | Normally Open (Outputs 12V) | Directly powering a low-current device | | NC | 12V | Normally Closed (Outputs 12V) | Directly powering a low-current device | | NO | Not Connected | Normally Open (Dry Contact) | General relay use | | NC | Not Connected | Normally Closed (Dry Contact) | General relay use |
| Error Symptom | Probable Cause | Solution | | :--- | :--- | :--- | | | Blown fuse on power supply or reverse polarity. | Check PSU, measure voltage at terminals 1 & 2 (must be 10-14V DC). | | Card beeps but lock doesn’t open | Lock wired to wrong relay (NO vs NC). | Swap lock wire from NO to COM or NC to COM. | | Lock opens for 1 second then closes | Insufficient power supply amperage (lock surge). | Upgrade to 12V DC 5A PSU. Add a capacitor across lock power. | | Continuous alarm after door closes | Door contact sensor (SEN) stuck or misaligned. | Check reed switch gap (<10mm). Set 16 0 # to disable temporarily. | | “Error” beep (two short beeps) | Command syntax error or user not found. | Re-enter command slowly. Use 14 to verify user exists. | | Master code not accepted | Someone changed it, or keypad is faulty. | Perform emergency reset (jumper method). | | RFID range is <1cm | Interference from metal or voltage drop. | Mount on non-metallic spacer. Check 12V at reader (terminal 2 & 10). |
To enter programming mode, you must use the Master Code. The factory default Master Code is . Entering and Exiting Admin Mode